Add to Cart
IEC Three Phase Electromechanical Energy Meter with ABS , Bakelite , PC Terminal cover
IEC Three Phase Electromechanical Energy Meter Four wire
The DT86 three-phase fore-wire meter is designed to meet the latest IEC62053-21,IEC62052-11 standards for measuring active energy in three-phase four-wire alternating current power grids. Connection is direct or by instrument transformers.. It has an average service life(MTTF)of 20 years and maximum overload capacity of 600%Ib.
Terminal block
The terminal block is molded of heat-and flame-resistant Bakelite . It is fixed in the extended meter base. The voltage test link can be located inside or outside of the meter case.
Driving element
The driving element consists of a voltage element and a current element, both of which are fixed on the aluminum alloy frame. It has a load curve compensation device and inductive load adjustment mechanism.
Register Cyclometer single, unidirectional, Jumping
Technical data:
| 
				 1  | 
			
				 Meter type  | 
			
				 DT86  | 
		|
| 
				 2  | 
			
				 Applicable Standards  | 
			
				 IEC62053-21 sw IEC62052-11  | 
		|
| 
				 3  | 
			
				 Accuracy class (according to IEC 60521)  | 
			
				 Transformer operated: Class 1 Direct connected: Class2 
  | 
		|
| 
				 4  | 
			
				 Average service life (MTTF)  | 
			
				 20 years  | 
		|
| 
				 5  | 
			
				 Basic current (lb)  | 
			
				 1.5 3 5 5 10 15 20 30  | 
		|
| 
				 6  | 
			
				 Maximum current (lmax)  | 
			
				 6 6 10 20 40 60 80 100??  | 
		|
| 
				 7  | 
			
				 Rating current of transformer  | 
			
				 5A Direct connection  | 
		|
| 
				 8  | 
			
				 Reference voltage Un  | 
			
				 3×57.7/100V,3×220/380V 3×230/400V,3×240/415V  | 
		|
| 
				 9  | 
			
				 Reference frequency fn  | 
			
				 50Hz,60Hz  | 
		|
| 
				 10  | 
			
				 Power losses in voltage circuit at? 50Hz Un  | 
			
				 1.0W/4.5VA  | 
		|
| 
				 11  | 
			
				 Power losses in current circuit at? 50Hz Un Ib  | 
			
				 <0.5VA  | 
		|
| 
				 12  | 
			
				 Non-running with no-load  | 
			
				 0.8~1.1Un  | 
		|
| 
				 13  | 
			
				 Starting current  | 
			
				 0.4%Ib 0.5%Ib  | 
		|
| 
				 14  | 
			
				 Mean temperature coefficient From 0.1Ib to Imax at unity PF From 0.2Ib to Imax at unity 0.5 lagging  | 
			
				 <0.08%/? <0.12%/?  | 
		|
| 
				 15  | 
			
				 Insulation level Withstand A. C. Voltage for 50Hz, 1min  | 
			
				 >2kV(when bakelite base>4kV) >6KV(when bakelite base>8kV)  | 
		|
| 
				 16  | 
			
				 Rated load torque at unity PF, Ib  | 
			
				 >800μMn  | 
		|
| 
				 17  | 
			
				 Weight of rotor  | 
			
				 48g  | 
		|
| 
				 18  | 
			
				 Weight of meter  | 
			
				 ?.5kg  | 
		|
| 
				 19  | 
			
				 Meter base  | 
			
				 Steel, Bakelite, PC  | 
		|
| 
				 20  | 
			
				 Meter cover  | 
			
				 Bakelite, transparent PC  | 
		|
| 
				 21  | 
			
				 Terminal cover  | 
			
				 ABS, Bakelite, PC  | 
		|
| 
				 22  | 
			
				 Register  | 
			
				 Cyclometer single, Unidirectional, Jumping  | 
		|
| 
				 23  | 
			
				 Option  | 
			
				 Reverse running stopper  | 
		|